Description
Type 2 SPD’s are designed to discharge the currents generated by indirect lightning strikes causing induced or conducted overvoltages on the power distribution network. They are characterized by an 8/20μs waveform (Imax). Higher is the Imax, more powerful they are. They are installed in the main distribution switchboard but also in sub-distribution board. They have a low residual voltage Up often compatible with the withstand voltage of the equipment to protect. If this is not the case or the cable length to the equipment is longer than 10m, another level of coordination with OVR T2-T3, OVR T3 will be needed. New original ABB part, traceable to the manufacturer. Availability and price on request.
Technical Specifications
| Type of Low Voltage Distribution System | TT ; TN-S |
|---|---|
| Nominal AC Voltage of the System (Uo) | 400 / 690 V |
| Maximum Continuous Operating Voltage (Uc) | (L-PE) 440 V |
| Rated Service Short-Circuit Breaking Capacity (Ics) | 100 kA |
| Discharge Current | Nominal (8 / 20 µs) 20 kA ; I (max, 8 / 20 µs) 40 kA |
| Impulse Current | I (imp, 10 / 350 µs, L-N) 2 kA |
| Number of Protected Poles | 2 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Poles | 2P |
| Rated Connecting Capacity | L/N Terminals with Solid Conductor 2.5 … 35 mm² ; L/N Terminals with Stranded Conductor 2.5 … 25 mm² ; PE Terminals with Solid Conductor 4 … 14 mm² ; PE Terminals with Stranded Conductor 2 … 14 mm² |
| Rated Voltage (Ur) | 230 V AC |
| Voltage Protection Level ( Up) | 1.5 kV ; (L-N) 1.25 kV ; (N-PE) 1.4 kV |
| Frequency (f) | 45 … 65 Hz |
| Degree of Protection | IP20 |
| Transmission Standard | Optic |
| Version | Plug-in |
| Product Type | QS |
| Ambient Air Temperature | Operation -40 … +80 °C ; Storage -40 … +80 °C |
| Maximum Operating Altitude Permissible | Without Derating 5000 m |
| Mounting Type | DIN-Rail |
| Standards | IEC 61643-1 / EN 61643-11 |
| Product Net Width | 35.6 mm |
| Product Net Height | 95 mm |
| Product Net Depth / Length | 58 mm |
| Product Net Weight | 0.24 kg |
| EAN | 3660308524577 |
| Catalog Description | OVR T2 1N 40-440 P TS QS Surge Protective Device |
| Short-Circuit Withstand Icc | 100 kA |
| Arrester Class | II |
| Number of Conductors | 2 |
| Preventive Maintenance Feature | No |
| Fuse Size | 2 modular spacing |
| Cross-Section (Across) | Maximum Conductor Solid-Stranded 25 mm² ; Maximum Conductor Flexible 16 mm² |
| Flammability According to UL94 | V-0 |
| Country of origin | Bulgaria |
| Customs tariff number | 85369095 |
| Manufacturer standard delivery time | 28 days |
| Packaging unit | Box x 1 |
| Product status (supplier data) | Active |
Independent distributor — not an authorised ABB dealer. All technical parameters are taken verbatim from the official ABB product data for this exact order code; packaging, customs and delivery data come from the supplier list entry for the same code.